Menu

Site Requirements

Plan Your IQ MAX Truck Wash Bay

IQ Max automatic truck wash bay on a sunny day. Equipped with 3D scanning technology that allows any size vehicle to be washed perfectly.

Planning Your Wash

What It Takes to Bring IQ MAX On-Site

IQ MAX fits new builds and existing facilities, from private fleet yards to public wash sites. Use the specifications below to plan your bay, utilities and site, then let our team review your layout before you build.

Vehicle Compatibility

Vehicles IQ MAX Can Wash

One system handles a mixed fleet, from standard vehicles to full tractor-trailers.
  • Tractor-trailer cabs
  • Full tractor-trailers
  • Buses & shuttle buses
  • Sprinter & cargo vans
  • Box & delivery trucks
  • Moving vans
  • Work trucks (plumbing, HVAC, ladder, tow)
  • Ambulances
  • Pumper trucks
  • RVs & 5th-wheel trailers
  • Standard-size vehicles

14′

Maximum vehicle height (13′ 6″ optimal)

10′

Maximum vehicle width, plus mirrors

91′

Maximum vehicle length (extended tractor-trailer)

IQ MAX is designed for street-legal vehicles. Mirrors and safety devices may extend beyond the 10′ body width.

Bay Dimensions

Size Your Wash Bay

Bay length is set by the longest vehicle you plan to wash.
Vehicle TypeMax Vehicle LengthBuilding LengthRail Length
Sprinter & delivery vans25′40′33′
RVs & 5th-wheel trailers47′65′55′
Tractor-trailers80′100′88′
Extended tractor-trailers91′110′99′

17′ – 18′

Bay Height

17′ minimum. 18′ recommended for new construction.

19′ – 20′

Bay Width

19′ recommended. Up to 20′ with wall-bracket mounting.

20′ – 25′

Column Spacing

20′ to 25′. Wider bays need a contractor-built support structure.

Planning notes

  • Add about 5′ of building length if you plan to install dryers.
  • The rail system must be fully enclosed in the building, with a clear path for the carriage.
  • Leave 3′ of clearance on the exit side for the energy chain.
  • Undercarriage spray can begin right at the bay entrance.

Utilities

Power, Water, Air & Drainage

Plan these services early. Our team can review them with your electrician, plumber and builder.

208–230V

Carriage Power

  • Dedicated 208–230V, 3-phase, 20A circuit
  • The carriage can’t be converted to other power sources

2 × 150A

Pump Power

  • Two high-pressure pumps, 150A each (standard)
  • 80A option at 460/480V
  • 120VAC control power for both pumps

5 CFM @ 90 PSI

Compressed Air

  • 5 CFM at 90 PSI, filtered and dry
  • Used for chemical aeration, blowdown and valve switching

2″ trunk line

Water Supply

  • Minimum 2″ trunk line from the water softener (supports up to 2 bays)
  • 30–50 PSI city flow pressure
  • 1″ ball valve to each pump stand
  • More than 2 bays requires a pressure and flow review

3 water lines

Water Connections

  • Hot soft water: ¾″ line from the water heater
  • Spot-free water: 1½″ line from the RO tank
  • RO reject/reclaim: 1½″ line from storage
  • Soft water recommended to reduce scaling

Center trench drain

Drainage

  • Center trench drain required
  • Floor sloped toward the trench or pit
  • Final drainage design is set by your builder and local sewer authority

Carriage Footprint

  • 17′Wide, including the energy chain
  • 15′ 6″Mounted above the floor
  • ~800 lbCarriage weight

Pump Stands

  • 2Compact pump stands for the equipment room
  • 30″ × 56″Footprint per stand (W × L)
  • 57″Height per stand

Site & Operations

Lot Size, Throughput & Staffing

Lot Size

Plan for about two acres per lane for tractor-trailers, or roughly one acre per lane for vehicles up to 45′.

Wash Times

Under 9 minutes for most fleet vehicles and about 15 minutes for a full tractor-trailer, or up to 4 large vehicles per hour.

Staffing

IQ MAX can run unattended 24/7. We recommend someone on-site or nearby for oversight, customer service and building local fleet relationships.

Fleet & Public Access

Wash Your Fleet. Sell Washes to the Public.

IQ MAX supports private fleet washing and public operation at the same time.

  • Employee fleets pass through free, with no hassle
  • Public customers pay at an electronic kiosk
  • Charges are processed automatically, with no staff involvement

Your fleet stays clean while outside customers add revenue, without disrupting daily operations.

White pickup truck entering a automatic truck wash bay powered by IQ Max, installed by Image Wash Systems.

FAQ

IQ MAX Site Requirement Questions

How tall does an IQ MAX wash bay need to be?

At least 17′, with 18′ recommended for new construction. IQ MAX washes vehicles up to 14′ tall.

How long does the building need to be for tractor-trailers?

About 100′ for tractor-trailers up to 80′ long, or 110′ for extended rigs up to 91′. Add roughly 5′ if you plan to install dryers.

What electrical service does IQ MAX require?

A dedicated 208–230V, 3-phase, 20A circuit for the carriage, plus service for two high-pressure pumps (150A each standard, or 80A at 460/480V).

What water supply does IQ MAX need?

A minimum 2″ trunk line from a water softener at 30–50 PSI, with hot soft water, spot-free RO water and an RO reject/reclaim line. Soft water is recommended.

Can IQ MAX be installed in an existing building?

Often, yes, as long as the bay meets the height, width and length requirements and has center trench drainage. Our team can review your layout.

Does someone need to run the wash?

No. IQ MAX can run unattended 24/7, though we recommend staff on-site or nearby for oversight and customer service.